Chemical Datasheet

Trespa TopLabPLUS Chemical Datasheet

Test Procedure

The test was conducted by applying 5 drops of each reagent on the surface, covered with a watchglass (except those marked **). Chemicals marked ** were tested saturated cotton wool ball covered by a bottle. The chemicals were tested over a period of 24 hours, rinsed off with water and evaluated.

Test Results - Definition
 

NO EFFECT No detectable stain, loss of gloss or change in work surface material.
EXCELLENT Slight stain or loss of gloss, but no change to the function, smoothnes or life of the work surface material.
GOOD A clearly discernable stain or loss of gloss, but no change to the function, smoothness or life of the work surface material.
FAIR Unacceptable staining or discernable deterioration or etching of the work surface material.
FAILURE Severe staining or moderate deterioration, pitting, cratering or etching of the work surface material.

Although the test was conducted professionally by an independent testing laboratory*, it is recommended that users conduct their own tests: convince yourself that TopLabPLUS is the only true multifunctional worktop!

Download Chemical Datasheet

* PSI: Professional Service Industries/Pittsburgh Laboratory Division